ANEMOMETRU CU FIR EXTENSIBIL PENTRU MASURARE PE CONDUCTE-STA2

Disponibilitate:

Stoc extern


DISPONIBIL PENTRU PRECOMANDA

2.632,63 lei

Pretul NU contine TVA

Stoc extern



    Solicita informatii despre produs

    Producator FIELDPIECE

    In-duct air balancing with fast response time
    Minimizes turbulence effect
    Hands free testing
    38″ telescoping probe in in-duct traversing
    Dual display shows combo of real-time CFM, air velocity, or temp

    The STA2 is a Hot-wire Anemometer built for the HVACR professionals’ air balancing needs.  The compact probe tip makes measuring air velocity directly in the duct a breeze.  It’s great for traversing a duct and automatically calculating CFM without the hassle and expense of a bulky hood.  The 38″ telescoping probe’s laser etched ruling and flattened edges allows techs to locate proper measurement points within a duct, and ensures that the probe is properly aligned.

    This in duct hot-wire anemometer quickly calculates CFM from air velocity and free area.  And with the intuitive interface, the STA2 makes it easy to capture the correct data.

    * Measures air velocity and temperature
    * Calculates CFM
    * Slim 38″ telescoping probe for in duct traversing
    * Fast response time
    * Dual display for combo of real-time CFM, air velocity, or temp
    * Depth and direction indicators
    * Minimizes turbulence effect with time/test point averages
    * Hands-free testing with stabilizing cone and magnetic hanger

    Includes:

    • Hot-wire Anemometer – STA2
    • Stabilizing Cone
    • Blow-molded Case with Padding

    Specifications

    • Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C),<90%RH
    • Temperature coefficient: 0.1 x (specified accuracy) per °C for 0°C to 18°C, 28°C to 50°C (32°F to 64°F,82°F to 122°F)
    • Operating environment: -4°F to 122°F (-20°C to 50°C) at <75%RH
    • Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
    • Battery: 9V
    • Battery life: 20-35 hours approx. (alkaline)
    • Battery indication: is displayed when the battery voltage drops below the operating level.
    • Auto Power off: after 15 minutes of inactivity if APO is active.
    • Over range: “OL” or “-OL” is displayed
    • Dimensions: 7.2 in (H) x 2.5 in (W) x 1.3 in (D) [185mm (H) x 65mm (W) x 35mm (D)]
    • Weight: 12 oz. (340g) including battery
    • Sensor type: Micro-glass bead thermistor.
    • Resolution: 1 fpm (0.01 m/s)
    • Range: 40-3960 fpm (0.20-20.00 m/s)
    • Accuracy: ± (5%+1 dgt) reading or ± (1%+1dgt)full scale
    • Units: fpm, m/s, km/hr, mph
    • Temperature Sensor type: Thermistor
    • Range: -4°F to 140°F (-20°C to 60°C)
    • Resolution: 0.1°C, 0.1°F
    • Accuracy:
      ±1.0°F for 32°F to 113°F
      ±2.0°F for -4°F to 32°F, 113°F to 140°F
      ±0.5°C for 0°C to 45°C
      ±1.0°C for -20°C to 0°C, 45°C to 60°C
    SKU: STA2 Categorii: ,
    Fieldpiece

    Fieldpiece

    Fisa tehnica produs: Descarca fisa tehnica